Fully Auto Loader Series

Fully Auto Loader Series

Keeping track with latest market development we are actively engaged in offering supreme quality Fully Auto Loader Series that is used in food and medicine. The offered moulding machine is manufactured by using superior quality components and cutting-edge technology by our adroit professionals. Furthermore, this moulding machine is tested on different quality parameters so as to ensure its quality.

Products offered by us are brought into application by a number of industries and appreciated for low media migration, low power consumption, easy operation and optimum filtration facilities. Since the day of our inception, we are working sincerely in order to meet demands of our clients across the globe and offer products with ensured satisfaction we have continuously created new scopes in the industry. Our devotion towards work and respect for clients have put in to win trust of our clients and building a lifelong relationship.

Salient Features

  • Fully Pneumatic Operation to ensure higher production rate and low cost maintenancerequirements.
  • Cost savings and easy maintenance.
  • Fully Pneumatic cylinders takes advantages of the low friction.
  • It can provide an advantage with unmatched response and cycle times.
  • Pneumatic cylinders complete its cycles faster and smoothly as per the given command.
  • The transfer of power and the speed is very easy to set up.Air could move at speeds that can beadjusted from low to high.
  • Advanced Plc microcontroller Based with user friendly touch screen interface (mould memory,ErrorMemory,password protection option).
  • Precise heating system using heating power adjustable in increment by 1% to 99%.
  • Programmable process control by PLC.
  • Consistent production and Repeatability.
  • Alarms for safety features.
  • Predictive maintainence Indicator.
S. No. PAGE 9 SPECIFICATION UNIT 2 CAVITY
1 PRODUCTION VOLUME ML 100 - 2000
2 PRODUCTION CAPACITY BPH 1800 - 2000
3 WORKING AIR PRESSURE Bar/Kg 10
4 BLOWING AIR PRESSURE Bar/Kg 25
5 AIR CONSUMPTION LOW CFM 35
6 AIR CONSUMPTION HIGH CFM 45
7 MAX. MOULD OPENING STROKE MM 110
8 MOULD CAVITY NO. NO. 2
9 MOULD THICKNESS MM 160
10 NECK DIAMETER MM 28 - 53
11 OPERATING PNEUMATICS
12 HEATER CONNECTION LOAD KW 32
RUNNING LOAD KW 15
13 HEATER TYPE INFRARED
14 LENGTH MM 2625
15 HEIGHT MM 2025
16 WIDTH MM 1600
17 WEIGHT KG 2200
S. No. PAGE 9 SPECIFICATION UNIT 2 CAVITY
1 PRODUCTION VOLUME ML 100 - 1000
2 PRODUCTION CAPACITY BPH 1800 - 2000
3 WORKING AIR PRESSURE Bar/Kg 10
4 BLOWING AIR PRESSURE Bar/Kg 25
5 AIR CONSUMPTION LOW CFM 35
6 AIR CONSUMPTION HIGH CFM 45
7 MAX. MOULD OPENING STROKE MM 110
8 MOULD CAVITY NO. NO. 2
9 MOULD THICKNESS MM 160
10 NECK DIAMETER MM 19 - 28
11 OPERATING PNEUMATICS
12 HEATER CONNECTION LOAD KW 32
RUNNING LOAD KW 15
13 HEATER TYPE INFRARED
14 LENGTH MM 2625
15 HEIGHT MM 2025
16 WIDTH MM 1600
17 WEIGHT KG 2000
S. No.10 PAGE SPECIFICATION UNIT 4 CAVITY
1 PRODUCTION VOLUME ML 100 - 1000
2 PRODUCTION CAPACITY BPH 3200 - 3600
3 WOR KING AIR PRESSURE Bar/Kg 10
4 BLOWING AIR PRESSURE Bar/Kg 25
5 AIR CONSUMPTION LOW CFM 55
6 AIR CONSUMPTION HIGH CFM 55
7 MAX. MOULD OPENING STROKE MM 110
8 MOULD CAVITY NO. NO. 4
9 MOULD THICKNESS MM 160
10 NECK DIAMETER MM 19 - 28
11 OPERATING PNEUMATICS
12 HEATER CONNECTION LOAD KW 42
RUNNING LOAD KW 22
13 HEATER TYPE INFRARED
14 LENGTH MM 3750
15 HEIGHT MM 2025
16 WIDTH MM 1600
17 WEIGHT KG 2800
S. No. 10 PAGE SPECIFICATION UNIT 4 CAVITY
1 PRODUCTION VOLUME ML 100 - 1000
2 PRODUCTION CAPACITY BPH 4400 - 4800
3 WORKING AIR PRESSURE Bar/Kg 10
4 BLOWING AIR PRESSURE Bar/Kg 25 - 30
5 AIR CONSUMPTION LOW CFM 55
6 AIR CONSUMPTION HIGH CFM 55
7 MAX. MOULD OPENING STROKE MM 110
8 MOULD CAVITY NO. NO. 4
9 MOULD THICKNESS MM 160
10 NECK DIAMETER MM 19 - 28
11 OPERATING PNEUMATICS
12 HEATER CONNECTION LOAD KW 42
RUNNING LOAD KW 22
13 HEATER TYPE INFRARED
14 LENGTH MM 3750
15 HEIGHT MM 2025
16 WIDTH MM 1600
17 WEIGHT KG 2800
S. No.12 PAGE SPECIFICATION UNIT 4 CAVITY
1 PRODUCTION VOLUME ML 20 - 300
2 PRODUCTION CAPACITY BPH 3600
3 WORKING AIR PRESSURE Bar/Kg 10
4 BLOWING AIR PRESSURE Bar/Kg 25
5 AIR CONSUMPTION LOW CFM 55
6 AIR CONSUMPTION HIGH CFM 55
7 MAX. MOULD OPENING STROKE MM 110
8 MOULD CAVITY NO. NO. 4
9 MOULD THICKNESS MM 160
10 NECK DIAMETER MM 19 - 28
11 OPERATING KW PNEUMATICS
12 HEATER CONNECTION LOAD KW 18
RUNNING LOAD 8
13 HEATER TYPE INFRARED
14 LENGTH MM 2850
15 HEIGHT MM 2000
16 WIDTH MM 1600
17 WEIGHT KG 2800
S. No.12 PAGE SPECIFICATION UNIT 4 CAVITY
1 PRODUCTION VOLUME ML 50 - 800ml
2 PRODUCTION CAPACITY BPH 3200 - 3600
3 WORKING AIR PRESSURE Bar/Kg 10
4 BLOWING AIR PRESSURE Bar/Kg 25
5 AIR CONSUMPTION LOW CFM 55
6 AIR CONSUMPTION HIGH CFM 55
7 MAX. MOULD OPENING STROKE MM 110
8 MOULD CAVITY NO. NO. 4
9 MOULD THICKNESS MM 160
10 NECK DIAMETER MM 19 - 28
11 OPERATING PNEUMATICS
12 HEATER CONNECTION LOAD KW 32
RUNNING LOAD KW 15
13 HEATER TYPE INFRARED
14 LENGTH MM 3250
15 HEIGHT MM 2025
16 WIDTH MM 1625
17 WEIGHT KG 2800
S. No. PAGE 11 SPECIFICATION UNIT 6 CAVITY
1 PRODUCTION VOLUME ML 20 - 300ml
2 PRODUCTION CAPACITY BPH 6000
3 WORKING AIR PRESSURE Bar/Kg 10
4 BLOWING AIR PRESSURE Bar/Kg 25
5 AIR CONSUMPTION LOW CFM 55
6 AIR CONSUMPTION HIGH CFM 55
7 MAX. MOULD OPENING STROKE MM 110
8 MOULD CAVITY NO. NO. 6
9 MOULD THICKNESS MM 160
10 NECK DIAMETER MM 19 - 28
11 OPERATING PNEUMATICS
12 HEATER CONNECTION LOAD KW 36
RUNNING LOAD KW 14
13 HEATER TYPE INFRARED
14 LENGTH MM 3675
15 HEIGHT MM 1900
16 WIDTH MM 1600
17 WEIGHT KG 3200
S. No. PAGE 11 SPECIFICATION UNIT 6 CAVITY
1 PRODUCTION VOLUME ML 100 - 1000ml
2 PRODUCTION CAPACITY BPH 6000 - 6600
3 WORKING AIR PRESSURE Bar/Kg 10
4 BLOWING AIR PRESSURE Bar/Kg 25 - 30
5 AIR CONSUMPTION LOW CFM 55
6 AIR CONSUMPTION HIGH CFM 150
7 MAX. MOULD OPENING STROKE MM 110
8 MOULD CAVITY NO. NO. 6
9 MOULD THICKNESS MM 160
10 NECK DIAMETER MM 19 - 28
11 OPERATING PNEUMATICS
12 HEATER CONNECTION LOAD KW 36
RUNNING LOAD KW 14
13 HEATER TYPE INFRARED
14 LENGTH MM 3675
15 HEIGHT MM 1900
16 WIDTH MM 1600
17 WEIGHT KG 3200
S. No. PAGE 11 SPECIFICATION UNIT 6 CAVITY
1 PRODUCTION VOLUME ML 50 - 750ml
2 PRODUCTION CAPACITY BPH 5500 - 6000
3 WORKING AIR PRESSURE Bar/Kg 10
4 BLOWING AIR PRESSURE Bar/Kg 25
5 AIR CONSUMPTION LOW CFM 55
6 AIR CONSUMPTION HIGH CFM 90
7 MAX. MOULD OPENING STROKE MM 110
8 MOULD CAVITY NO. NO. 6
9 MOULD THICKNESS MM 160
10 NECK DIAMETER MM 19 - 28
11 OPERATING PNEUMATICS
12 HEATER CONNECTION LOAD KW 36
RUNNING LOAD KW 14
13 HEATER TYPE INFRARED
14 LENGTH MM 3675
15 HEIGHT MM 1900
16 WIDTH MM 1600
17 WEIGHT KG 3200